Skip to content

Tower

Victoria Falls does not have a dedicated Tower frequency, as such all Tower responsibilities are assumed by Falls Approach (FVFA_APP). Under no circumstances should FVFA_TWR ever be opened without prior approval from staff.

FVFA CTR Altitude - 4500ft.

Visual Flight Rules (VFR) Aircraft

Type Circuit Altitude
Jet 4500ft
Turbine / Piston 4500ft
Helicopter 4500ft
  • All circuits are conducted left hand normally, but may be conducted right hand at the discretion of the Tower controller.

Circuit Clearance

ZSABC, hold position, after departure Runway XX, L / R hand circuits, not above altitude 4500ft, report L / R downwind Runway XX.

Circuit Clearance (Non STD)

ZSABC, hold position, after departure Runway XX, non standard L / R hand circuits, not above altitude 4500ft, report non standard L / R downwind Runway XX.

VRPs

No VRPs are publically available at Victoria Falls.

VFR Procedures

Info

There are no Standard VFR Routings across the Victoria Falls CTR.

Entry Clearance

ZSABC, cleared to enter the CTR from the N / S / W / E, not above altitude 4500ft, report L / R downwind Runway XX.

Exit Clearance

ZSABC, hold position, after departure Runway XX, exit the CTR to the N / S / W / E , not above altitude 4500ft, report exiting the CTR.

Wake Seperation

Arrivals (nm)

Lead J H M L
J
H 6 4
M 7 5 5
L 8 6 5 5

Departures (mins)

Lead J H M L
J
H 2
M 3 2
L 3 2 2

Takeoff Phraseology

Takeoff (Full Length)

ZSABC, Runway XX, wind 080 degrees at 9 knots, cleared for takeoff, report airborne.

Takeoff (Intersection)

ZSABC, Runway XX via XX, wind 080 degrees at 9 knots, cleared for takeoff, report airborne.